Wild Country Plumbing - Your authorized dealer for Econoburn products in Colorado proudly presents:
Econoburn™ Specifications
Boiler Model EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Design Applicaton Indoor Indoor Indoor Indoor Outdoor Outdoor
Btu Output 100,000 150,000 200,000 500,000 150,000 200,000
 
Boiler Dimensions EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Depth 47″ / 119.4cm 47″ / 119.4cm 47″ / 119.4cm 63″ / 160cm 54.25″ / 137.8cm 54.25″ / 137.8cm
Width 25″ / 63.5cm 26″ / 66cm 30″ / 76.2cm 41″ / 104.1cm 48.4″ / 122.9cm 48.4″ / 122.9cm
Height 60.25″ / 153cm 63.75″ / 161.9cm 64.25″ / 163.2cm 76″ / 193cm 80″ / 203.2cm 80.5″ / 204.5cm
Weight Empty 1,560 Lbs / 708 kg 1,670 Lbs / 757 kg 1,980 Lbs / 898 kg 3,405 Lbs / 1,544 kg ~1,800 Lbs/ 816 kg ~2,100 Lbs / 953 kg
 
Firebox Dimensions EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Depth 23″ / 58.4cm 23″ / 58.4cm 23″ / 58.4cm 32″ / 81.3cm 23″ / 58.4cm 23″ / 58.4cm
Width 15″ / 38.1cm 16″ / 40.6cm 21″ / 53.3cm 27″ / 68.6cm 16″ / 40.6cm 21″ / 53.3cm
Height 25″ / 63.5cm 28″ / 71.1cm 29″ / 73.7cm 39″ / 99.1cm 28″ / 71.1cm 29″ / 73.7cm
Maximum Log length 21″ / 53.3cm 21″ / 53.3cm 21″ / 53.3cm 33″ / 83.8cm 21″ / 53.3cm 21″ / 53.3cm
Firebox Door Height 12″ / 30.5cm 12″ / 30.5cm 12″ / 30.5cm 12″ / 30.5cm 12″ / 30.5cm 12″ / 30.5cm
Firebox Door Length 15″ / 38.1cm 15.75″ / 40cm 20.5″ / 52.1cm 27.5″ / 69.9cm 15.75″ / 40cm 20.5″ / 52.1cm
 
Piping Data EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Water Volume 30 Gal / 114 L 37 Gal / 140 L 42 Gal / 159 L 95 Gal / 360 L 37 Gal / 140 L 42 Gal / 159 L
Supply Pipe (female connection) 2″ 2″ 2″ 4″ 2″ 2″
Return Pipe (female connection) 2″ 2″ 2″ 4″ 2″ 2″
Min Boiler Loop Size 1-1/4″ 1-1/4″ 1-1/2″ 3″ 1-1/4″ 1-1/2″
Fill/Drain Valve Size 3/8″ 1-1/4″ 1-1/2″ 1-1/2″ 1-1/4″ 1-1/2″
 
Flue Dimensions EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Flue Outlet Diameter 8″ 8″ 8″ 12″ 8″ 8″
Height to Center of Flue 47.25″ 50.75″ 51.25″ 61.5″ 50.75″ 51.25″
 
Operating Data EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Max Operating Temperature 210° F / 99° C
Max Operating Pressure 30 PSI / 207 kPa
Output Temperature (range) 170° F – 200° F / 77° C – 93°
C
Specified Fuel Wood (recommended moisture content: 15-22%)
Minimum Draft Required -0.02 to -0.06 inch WC / -0.005 kPa to
-0.015 kPa
Flue Gas Temperature 280° F – 400° F / 138° C –
204° C
 
Electrical Data EBW-100 EBW-150 EBW-200 EBW-500 EBW-150-O EBW-200-O
Boiler Power Requirement 110 volt, 15 amp
Electrical Consumption (watts) 100 175 175 200 175 175
Aquastat Overheat Setting 220° F / 104° C
Electrical Consumption 5 amps